RCA 12at7 data values (v,mA) first line is not part of original RCA data, but can be used in modeling overload region. vgc = +1.0 0,0.145 4,1.62 9,2.72 21,4.64 82,12.37 117,17.69 vgc = 0.0 14,0.04 41,0.26 72,0.57 107,0.95 129,1.25 161,1.71 203,2.38 vgc = -1.0 50,0.04 79,0.20 112,0.45 131,0.61 166,0.94 181,1.09 216,1.49 264,2.13 vgc = -2.0 92,0.03 121,0.12 157,0.27 189,0.47 204,0.59 234,0.87 284,1.44 320,1.89 vgc = -3.0 150,0.03 192,0.17 235,0.40 269,0.64 302,0.93 331,1.21 371,1.69 vgc = -4.0 200,0.04 235 0.14 275,0.32 315,0.60 384,1.22 412,1.49 vgc = -5.0 250,0.03 290,0.15 336,0.39 367,0.59 398,0.83 425,1.05 454,1.30 vgc = -6.0 300,0.02 330,0.12 375,0.32 412,0.55 453,0.82 495,1.13 vgc = -7.0 338,0.03 371,0.13 425,0.37 459,0.56 495,0.77 527,0.98 vgc = -8.0 362,0.03 391,0.08 421,0.18 462,0.35 506,0.57 557,0.86 vgc = -10.0 409,0.05 444,0.13 477,0.22 507,0.33 532,0.41 557,0.50 598,0.67